Made in SwitzerlandLocal warehouses · Australia · Canada · USAVerify your product
Sequence reference

Peptide sequence numbering.
Keep the reference frame.

Read a fragment range without confusing the parent position, the new fragment position or a terminal modification.

A notation such as peptide (2–4) identifies positions within a reference sequence. It does not mean a two-residue peptide, and the last number is not the fragment length. The range includes both endpoints. Understanding that convention makes a sequence annotation much easier to check.

This guide uses an invented five-residue example so the numbering can be followed without relying on a product name. The same reading method helps with scientific papers, sequence databases and structural drawings. Start by identifying the reference chain; then distinguish its residue positions from the numbering used for an isolated fragment.

Start at the N-terminus

In the usual linear representation, the chain runs from its N-terminal end to its C-terminal end. Residue numbering follows that direction. N and C refer to the ends of the peptide backbone, rather than the first letters of amino-acid names. The official IUPAC polypeptide conventions describe this numbering direction.

For our example, write Ala–Gly–Ser–Thr–Lys, or AGSTK. The first residue is alanine and the fifth is lysine. Reversing the written order would describe a different sequence. Read a figure's direction labels before assuming that its left edge is the N-terminus.

An illustrative five-residue reference chain
Reference positionThree-letter symbolOne-letter symbol
1AlaA
2GlyG
3SerS
4ThrT
5LysK

A fragment range retains the parent positions

The fragment (2–4) of this example is Gly–Ser–Thr. It contains three residues: positions 2, 3 and 4 of the parent. The arithmetic is 4 − 2 + 1 = 3. Omitting the final plus one is an easy way to miscount a short fragment.

IUPAC's fragment convention uses the first and last retained positions of the named parent. That is why the parent name is part of the notation: a range without a reference sequence cannot identify the residues. See IUPAC section 3AA-22.6.

If the isolated Gly–Ser–Thr chain is renumbered from its own N-terminus, glycine becomes fragment position 1. It remains parent position 2. Both descriptions can be correct, provided the author states which frame is being used.

Parent numbering and fragment numbering answer different questions
ResiduePosition in the parentPosition in isolated fragment (2–4)
Gly21
Ser32
Thr43

Terminal groups are a separate structural field

A range specifies the selected residues. It does not, on its own, settle every detail at the new ends. For example, writing a terminal amide explicitly records an end-group modification. It does not add another amino-acid residue to the count. The IUPAC amide addendum illustrates that notation.

Keep the sequence and terminal annotation together when transcribing a name. A short label copied without its suffix can lose information even when every residue letter is preserved. The same principle applies to a separately stated N-terminal group: record the group instead of treating it as an extra numbered amino acid.

A substitution is different from a shorter fragment

Consider two operations on the example. Selecting positions 2–4 gives Gly–Ser–Thr. Replacing the residue at parent position 3 gives a modified five-residue chain. The first operation changes which part of the parent is retained. The second changes a position within that reference chain.

Write the operation in your notes before comparing two names. A shared range does not establish that all substitutions are the same; a shared number of residues does not establish a shared sequence. This is particularly helpful when a paper introduces several numbered analogues in one table.

A practical annotation check

  1. Record the complete parent sequence or its database accession.
  2. Confirm which end is numbered first.
  3. Expand the stated fragment range and count both endpoints.
  4. Keep parent positions separate from any new fragment numbering.
  5. Copy terminal groups, substitutions and configuration annotations alongside the sequence.

A clean annotation can therefore contain several fields: reference chain, retained positions, written fragment and terminal state. These fields make a structural description reproducible. They are not evidence of a material's analytical identity or an experimental outcome.

The Semax and ACTH-fragment example shows why a shared fragment-related name still needs a residue-by-residue comparison. The molecular-mass guide explains a different check that can be made once a complete structure has been defined.

Preparing a sequence-reference brief? Record the complete chain, numbering and terminal groups together. For a general document or presentation requirement, use the laboratory specification enquiry.

Scientific and nomenclature references

  1. IUPAC polypeptide conventions: residue-numbering direction
  2. IUPAC section 3AA-22: modifications and partial sequences
  3. IUPAC amide addendum: terminal-group notation